Please help me out ASAP!! The problem is that when I query, it looks like my device is properly recognized and no Error, but no data from test instruments come. In order to enable the control, try reloading the latest cash file by pressing the right button of your mouse and clicking update function label. But I need to collect the frequency value too from the instrument. What options do the DSOseries oscilloscopes offer for saving data?

Uploader: Tygom
Date Added: 22 June 2006
File Size: 64.90 Mb
Operating Systems: Windows NT/2000/XP/2003/2003/7/8/10 MacOS 10/X
Downloads: 74750
Price: Free* [*Free Regsitration Required]

In order to enable the control, try reloading the latest cash file by pressing the right button of your mouse and clicking update function label. Refer Watlow manual for reference. But it seems like it is tracing the data with respect to data points as shown below.

If I delete profile how step numbers will be affected?

But it seems like it is tracing the data with respect to data points as shown below. If I want to create New profile should I start step numbering from 1 or 7? Measurement and Automation Explorer gets different Visa resource names for serial ports each time I run it. How do figure out what hex values to write in the write buffer?

  HITI PHOTO PRINTER S400 DRIVER DOWNLOAD

I have tried with both the IVI function as well as the driver specific function. I am using Query TraceArray. Here as shown in below screenshot, I am getting the amplitude with respect to data points upto Hi All, I am new to this group. So I am not finding any explicit command to fetch the corresposnding frequency values for each data point. I’ve been struggling with this error for a while, trying to unflatten, reflatten, and convert strings with no avail.

Agilent Technologies / Keysight Technologies 8563EC

Programmable Current Sinking In general, current sinking is a fixed value at some percentage of the full scale current output. Auto-suggest helps you quickly narrow down your search results by suggesting possible matches as you type.

Is it the problem that the command type sent from labview is string so that my chip cannot recognize that? Please suggest me some material llearning which I can understand 85663ec aspects of labview.

Solved: Query ID for HPA Spectrum Analyzer – Discussion Forums – National Instruments

The chip is set to send a feedback signal once it successfully recieve the command. Message 1 of 7. Claim or contact us about this channel. I use this same routine to querya couple Ex supplies and it works fine on them.

  GENIUS USB CAMERA VIDEOCAM EYE V2.0 DRIVER DOWNLOAD

Instrument Control (GPIB, Serial, VISA, IVI)

Why did you decide not to use 8563dc existing driver? It seems, when the program trace the data it only trace amplitude. Are you the publisher? AUTO” be used for?

But in the instrument, the graph is always amplitude versus frequency instead of amplitude vs data point. Message 2 of 7. Browse the Latest Snapshot. I need to create profile, Wirte steps, load profile, Run profile etc.

I am conducting a basic test to check if the chip can communicate well with lavview.

I test it succefully on a third party serial communication software attached the capture pic belowbut it seems doent’ work on labview. What should I perform when the EA settings cannot be remotely controlled in Web server Web browser control mode?

How can I ensure that my device is properly recognized? Please, any help is very welcome.